7 kW Air-Cooled Standby Generator
1-866-734-3735 Toll Free

                                                                                     

Generac Guardian Generators > Guardian Model 05240 > 7 kW Air Cooled Home Standby Single Phase Genset

7 kW Air-Cooled Standby Generator 

GUARDIAN 7 kW Air-Cooled Standby Generator
7 kW  10 kW  13 kW

Click to Compare Models

Find generator sizes:  7 kW 10 kW 13 kW 20 kW up to 150 kW Single and Three Phase Commercial Generators

GUARDIAN 7 kW Air Cooled Standby Generator 7000 watts

 

GUARDIAN®

 

GUARDIAN’s 7 kW is clearly the most affordable automatic standby generator on the market. For under $2,000 you can power all of your home’s essential circuits, including your living room, family room, kitchen, bathroom, bedroom, furnace, well pump and window air conditioner.

There’s no need to worry about individual items because everything on the circuits you choose is protected… lights, plug-in appliances, electronics, air conditioner… everything!

Plus, GUARDIAN’s 7 kW comes as a pre-packaged, pre-wired system, so it’s the easiest system on the market to install. That’s just one more reason why GUARDIAN is America’s #1 selling brand.
Click for Spec Sheet 
 
Installation Video 

GUARDIAN® air-cooled generators are pre-wired and pre-packaged, making installation easy for you, your electrical contractor or one of our authorized dealers. To view our installation video (242 MB), please click on the image to the right.

A DVD of this installation video along with an Installation Guidelines booklet will be packaged with every generator purchased.

Note: Neither the installation video nor the Installation Guidelines booklet replace or supersede any information contained the Owner’s Manual, Installation Guide, technical manuals or any other documents packaged with your equipment.



"Installation" Video

Generator Set

Model Number 05240
Rated Power LP (kW) 7
Rated Power NG (kW) 6
Voltage @ 60 Hz 120/240
Phase Single
Frequency 60 Hz
Amps LP 58.3/29.2
Amps NG 50.0/25.0
Engine/Alternator RPM 3600/3600
Engine 410cc
14.5 HP
Generac OHVI
Single Cylinder
Fuel Consumption LP (cu.ft./hr.)/(gal./hr.) 54 (1.47)
Fuel Consumption NG (cu.ft./hr.) 119
EPA/CARB Certified Yes
Fuel Natural Gas/LP Vapor
Engine Cooling Air
UL 2200 (US and Canada) Yes
Main Line Circuit Breaker 30 Amp
Dimensions (L" x W" x H") 48 x 24 x 28-1/4
Unit Wt. (lbs.) 336

Controls
Engine Start Sequence Cyclic cranking: 7 sec. on, 7 sec. rest. 90 sec. maximum duration
Automatic Low Oil Shutdown Standard
Overspeed Shutdown Standard, 72 Hz
Overcrank Protection Standard
Automatic Voltage Regulator with Over-Voltage Protection Standard
Engine Warmup 10 seconds
Engine Cool-Down 1 minute
Safety Fuse Standard
2.5 Amp Timed Trickle Battery Charger Standard
Auto Switch Automatic start on utility failure/7 day exercise
Off Switch Stops unit. Power is removed. Control and charger still operate
Manual / Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place
Full Monitoring System Oil pressure, coolant temperature, engine speed, coolant level, cranking time, starter lockout, utility sensing
Shutdown and LED Indicators Overspeed and overcrank, low oil pressure, high coolant temperature, low coolant level, low fuel pressure, low battery voltage
 
Transfer Switch
Engine Start Sequence Cyclic cranking: 7 sec. on, 7 sec. rest. 90 sec. maximum duration
Automatic Low Oil Shutdown Standard
Overspeed Shutdown Standard, 72 Hz
Overcrank Protection Standard
Automatic Voltage Regulator with Over-Voltage Protection Standard
Engine Warmup 10 seconds
Engine Cool-Down 1 minute
Safety Fuse Standard
2.5 Amp Timed Trickle Battery Charger Standard
Auto Switch Automatic start on utility failure/7 day exercise
Off Switch Stops unit. Power is removed. Control and charger still operate
Manual / Test (start) Start with starter control, unit stays on. If utility fails, transfer to load takes place
Full Monitoring System Oil pressure, coolant temperature, engine speed, coolant level, cranking time, starter lockout, utility sensing
Shutdown and LED Indicators Overspeed and overcrank, low oil pressure, high coolant temperature, low coolant level, low fuel pressure, low battery voltage

Features and Benefits

Breakthrough Design, Advanced Technology
GUARDIAN® and GUARDIAN QuietSource™ air-cooled generators offer the most wattage and greatest starting power in their class. The GUARDIAN QuietSource™ 16 kW can start a 5-ton and 3-ton A/C unit or two 4-ton units. The 13 kW can start a 4-ton and the 10 kW can start a 3-ton.

Whisper-Test™ (GUARDIAN QuietSource™ models only)
Reduces noise to a whisper by lowering engine speed during the generator’s weekly self-test. The Whisper-Test sound level is comparable to a car at idle and is 50% quieter (59 dBA) than the competition.

Pre-wired and Pre-packaged
GUARDIAN’s pre-packaged, pre-wired air-cooled systems make installation easy and, therefore, incredibly affordable for the do-it-yourselfer! Air-cooled models come with a pre-wired automatic transfer switch, outdoor connection box and composite mounting pad.

OHVI® Industrial Engine
Generac’s OHVI® (Overhead Valve Industrial) engines have been specifically designed for generator demands. These engines offer the finest lubrication technology available providing instantaneous disbursement of lubricant to all engine parts. They also feature an automotive spin-on oil filter for simplified routine maintenance.

Superior Electrical Protection
The air-cooled 10, 13 and 16 kW models feature an electronic governor, which maintains steady speed and eliminates voltage drop when loads are applied. This, as well as the automatic voltage regulator, provides a smooth rate of electricity, which is especially important for sensitive electronic devices such as computers.

Superior Paint
New textured, powder coat paint process provides consistent coverage and better bonding to seams and exposed edges providing durability and a long-lasting, tough finish.

Aluminum Enclosure (optional on GUARDIAN QuietSource™ models)
GUARDIAN QuietSource™ generators are available in a corrosion-resistant aluminum enclosure to better withstand the elements. This option is especially important for homes in southern and coastal communities.

Automatic Exerciser
An automatic seven (7) day test of your system allows you to verify that your generator is in peak operating condition at all times.

Automatic Transfer Switch
The automatic transfer switch automatically switches the source of power from the utility to the generator within seconds of a power outage. Because it’s automatic, you never have to flip a switch.

Convenient Fuel Supply
GUARDIAN and GUARDIAN QuietSource™ generators operate on natural gas or LP gas service. This provides you with unlimited run time during extended utility power failures.

Maintenance Friendly
Air-cooled models feature a hinged top and removable front panel. Liquid-cooled models feature large, removable doors. This provides easy and quick access for maintenance and servicing.

Automatic Safety Shutdowns
Automatic safety shutdowns protect the engine and generator in the event of low oil pressure, high temperature, overspeed and/or overcrank.

Protective Enclosure
The enclosure protects your generator from harmful weather and includes key locks for security. Sound-absorbing panels also reduce exterior noise levels.

Battery Charger
A built-in battery charger ensures that the battery remains at an optimum performance level.

Easy Installation
GUARDIAN’s air-cooled pre-packaged, pre-wired systems make installation the most affordable and easiest installation possible.

UL-Listed
For your safety, GUARDIAN standby generators are UL 2200 listed and all transfer switches are UL 1008 listed. This validates safety and kilowatt ratings.

EPA and CARB Emission Requirements
Generators up to 25kW must comply with EPA and CARB emissions requirements. All GUARDIAN generators up to 25 kW meet these requirements.

Made in USA
Manufactured by Generac Power Systems, we design and build our complete product from the controls to the enclosures, to our air-cooled engines specifically designed for generators. This ensures that all GUARDIAN and GUARDIAN QuietSource™ products are built to our highest standards.

Installation Drawings

GUARDIAN Power Rating Bulletin Number
7, 10 & 13 kW Air-Cooled 0F9424
40 kW Liquid-Cooled (California Emissions) 0D5335


GUARDIAN QuietSource™ Power Rating Bulletin Number
16 kW Air-Cooled 0F9424


GUARDIAN QuietSource™ Liquid-Cooled (20-45kW) and
GUARDIAN Elite Commercial Series Liquid-Cooled Power Rating:
Bulletin Number
20kW 1.5L 0F7555A-A
20kw and 25kW 1.6L 0G1044-A
35kW and 45kW 2.4L 0G0325-B
60kW 0F9577-B
70kW 6.8L 0F6287-B
80kW 4.6L 0G1088
80kW 5.4L thru 150kW 0F6289-B

GUARDIAN installation drawings are available to download as Adobe Acrobat PDF files. Click on the PDF link to view the document.
HyperLink

Transfer Switch

Transfer Switches for GUARDIAN Air-Cooled Models The transfer switch monitors utility power and signals the generator to start when utility power is interrupted. When utility power returns, the transfer switch returns the electrical load from the generator back to the utility. This ensures your most important electrical loads are powered, within seconds, even when you’re away. Unlike other pre-packaged systems, GUARDIAN includes an automatic transfer switch as standard equipment with all models.

This transfer switch is the difference between a truly automatic generator set and just another generator. No toggles to flip, no knobs to turn, no extension cords to run when you lose utility power. You will have the comfort and peace-of-mind knowing that your GUARDIAN standby generator does everything for you... automatically.
  • A two pole, 100-amp automatic transfer switch is standard equipment on models 05336T.
  • A two pole, 200-amp automatic transfer switch is standard equipment on models 05324T and 05259T.
  • A two pole, 200-amp Service Disconnect transfer switch is standard equipment on model 05261T.
These transfer switches are also available for liquid-cooled models or as an alternative to be purchased separately.

Standard Transfer Switch
Service Disconnect Transfer Switch
Model Number RTS-N-100A3 RTS-N-200A3
No. of Poles 2 2
Current Rating (amps) 100 200
60 Hz Phase Single Single
Voltage Rating (VAC) 250 250
Utility Voltage Monitor (fixed)
Pickup 70% 70%
Dropout 60% 60%
Return to Utility 15 seconds 15 seconds
Exerciser 15 min. weekly * Standard Standard
UL 1008 Listed Standard Standard
Dimensions (H" x W" x D") 20x15x7 20x15x7
Enclosure Type NEMA 3R Outdoor Rated NEMA 3R Outdoor Rated
Unit Wt. (lbs.) 35 35
* When used with liquid-cooled models. If used with air-cooled models exercise duration will be 12 minutes.


Click for
Spec Sheet

 
Service Disconnect Transfer Switch
Model Number RTS-E-100A3 RTS-E-200A3
No. of Poles 2 2
Current Rating (amps) 100 200
60 Hz Phase Single Single
Voltage Rating (VAC) 250 250
Utility Voltage Monitor (fixed)
Pickup 80% 80%
Dropout 60% 60%
Return to Utility 15 seconds 15 seconds
Service Disconnect Circuit Breakers (2) 100 Amp HACR Type (2) 200 Amp HACR Type
Exerciser 15 min. weekly * Standard Standard
UL 1008 Listed Standard Standard
Dimensions (H" x W" x D") 23.5x13x7.4 23.5x15.8x7.4
Enclosure Type NEMA 3R Outdoor Rated NEMA 3R Outdoor Rated
Unit Wt. (lbs.) 50 55
* When used with liquid-cooled models. If used with air-cooled models exercise duration will be 12 minutes.

Warranty

Warranties Applicable to: Warranty Type Warranty Coverage PDF
Standby - Air-Cooled Standard 2 Year Air-CooledStby
Standby - Liquid-Cooled 45kW and Below Standard 2 Year Liquid-CooledStby45&Below
Standby - Liquid-Cooled 50kW and Above Standard 2 Year Liquid-CooledStby50&Above


Installation Bulletins: Bulletin Type Bulletin Number
Air-Cooled Units Improper installation of flex fuel line IIB05 - 1 S
 
GUARDIAN warranty policies are available to download as Adobe Acrobat PDF files. Click on the PDF link to view the document.
Get Adobe Reader

 

 

7 kW Air-Cooled Standby Generator

                                                                                     

Generac Guardian Generator > Guardian Model > 7 kW Air Cooled Single Phase

 Home Standby Generators by Generac Guardian 

Copyright 2005 Power Generators

 
Google