These Home Standby - 7kW - 12kW -15kW Generator Generac Guardian have been discontinued for 2006 -
Please
view our replacement generators sizes 7 kW, 10 kW and 13 kW ![]()
![]() |
|||
|
INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in "IMPROVING POWER BY DESIGN." But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. TEST CRITERIA: > PROTOTYPE TESTED > SYSTEM TORSIONAL TESTED > NEMA MG1-22 EVALUATION > MOTOR STARTING ABILITY |
SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a GENERAC POWER SYSTEM. GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. |
||
|
. |
|||
|
. |
|||
![]() |
•Generac (OHVI) Design |
Maximizes engine "breathing" for increased fuel efficiency. Cylinder walls run cooler, reducing oil consumption. Because heat is the primary cause of engine wear, the OHVI has a significantly longer life than competitive engines. |
|
•"Spiny-lok" cast iron cylinder walls |
Rigid construction and added durability provide long engine life. |
|
|
ENGINE•Electronic ignition, spark advance and compression release |
These features combine to assure smooth, quick starting every time. |
|
|
•Full pressure lubrication system |
Superior lubrication to all vital bearings means better performance, less maintenance and significantly longer engine life. |
|
|
•Low oil pressure shutdown system |
Superior shutdown protection prevents catastrophic engine damage due to low oil. |
|
|
•High temperature shutdown |
Prevents damage due to overheating. |
|
|
•Revolving field |
Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. |
|
|
•Skewed stator GENERATOR |
Produces a smooth output waveform for compatibility with electronic equipment. |
|
|
•Displaced phase excitation |
Maximizes motor starting capability. Provides more surge capability than brushless generator designs. |
|
|
•Automatic voltage regulation |
Regulates the output voltage to ±2% prevents damaging voltage spikes. |
|
|
•UL 2200 Listed |
For your safety |
|
|
•Fully Automatic |
Transfers your vital electrical loads to the energized source of power. |
|
|
•Remote MountingTRANSFERSWITCH |
Mounts near your existing distribution panel for simple, low cost installation. |
|
|
•UL Listed |
For your safety |
|
|
•Manual/Auto/Off switch |
Selects the operating mode. |
|
|
•Utility voltage sensing |
Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage. |
|
|
•Utility interrupt delay |
Prevents nuisance start-ups of the engine, set point approximately 10 seconds. |
|
|
•Engine warm-up MICROPROCESSOR CONTROL |
Ensures engine is ready to assume the load, setpoint approximately 10 seconds. |
|
|
•Engine cool-down |
Allows engine to cool prior to shutdown, setpoint approximately 1 minute. |
|
|
•Seven day exerciser |
Operates engine to prevent oil seal drying and damage between power outages. |
|
|
•Timed Trickle Battery charger |
Maintains battery amperage to insure starting. |
|
|
•Main Line Circuit Breaker |
Protects generator from overload. |
|
|
•Weather protective enclosure |
Ensures protection against mother nature. Hinged key locking roof panel for security. Electrostatically applied epoxy paint for durability. |
|
|
•Enclosed critical grade muffler UNIT |
Quiet, critical grade muffler is mounted inside the unit to prevent injuries. |
|
|
•Small, compact, attractive |
Makes for an easy, eye appealing installation. |
|
|
•Pre-wired External Connection Box •1’ Flexible Fuel Line INSTALLATION |
Easy Installation - Virtually all hardware included, plus step-by-step photographed Installation Guide. |
|
|
•Composite Mounting Pad SYSTEM |
||
|
•Pre-wired conduits |
||
|
•UL Listed wire nuts |

|
GENERATOR Model 04389(7kW) Model 04456 (12kW) |
Model 04390 (15kW†) |
|
Rated Maximum Continuous Power Capacity (LP)................................... 7,000 Watts* 12,000 Watts* |
15,000 Watts* |
|
Rated Maximum Continuous Power Capacity (NG)...................................6,000 Watts* 12,000 Watts* |
13,000 Watts* |
|
Rated Voltage................................................................................................120/240 120/240 |
120/240 |
|
Rated Maximum Continuous Load Current |
|
|
120 Volts ................................................................................................ 50.0 NG/58.3 LP 100.0 NG/100.0 LP |
108.3 NG/125.0 LP |
|
240 Volts ................................................................................................ 25.0 NG/29.2 LP 50.0 NG/ 50.0 LP |
54.2 NG/62.5 LP |
|
Main Line Circuit Breaker ............................................................................. 30 Amp 50 Amp |
60 Amp/70 Amp† |
|
Phase ................................................................................................................. 1 1 |
1 |
|
Number of Rotor Poles .......................................................................................2 2 |
2 |
|
Rated AC Frequency ........................................................................................60Hz 60Hz |
60Hz |
|
Power Factor .......................................................................................................1 1 |
1 |
|
Battery Requirement (not included) ..........................................................Group 26/26R Group 26/26R |
Group 26/26R |
|
12 Volts and 12 Volts and |
12 Volts and |
|
350 Cold-cranking 525 Cold-cranking |
525 Cold-cranking |
|
Amperes Minimum Amperes Minimum |
Amperes Minimum |
|
Shipping Weight (Includes Transfer Switch) .............................................. 375Pounds 470 Pounds |
487 Pounds |
|
Dimensions (L" x W" x H")....................................................................... 48 x 24 x 28-1/4 48 x 24 x 28-1/4 |
48 x 24 x 28-1/4 |
|
Sound output in dB(A) at 23 ft. with generator operating at full load................ 68 70.5 |
71.5 |
|
†15kW on LP fuel requires electrical upgrade kit 04578. Kit includes power harnesses and 70 amp 2-pole circuit breaker. |
|
|
ENGINE Model 04389 (7kW) Model 04456 (12kW) |
Model 04390 (15kW) |
|
Type of Engine........................................................................................GENERAC OHVI GENERAC OHVI V-TWIN |
GENERAC OHVI V-TWIN |
|
Number of Cylinders........................................................................................... 1 2 |
2 |
|
Rated Horsepower................................................................................. 14.5 @ 3,600 rpm 26 @ 3,600 rpm |
30 @ 3,600 rpm |
|
Displacement...................................................................................................410cc 763cc |
992cc |
|
Cylinder Block........................................................................................ Aluminum w/Cast Aluminum w/Cast |
Aluminum w/Cast |
|
Iron Sleeve Iron Sleeve |
Iron Sleeve |
|
Valve Arrangement.................................................................................. Overhead Valve Overhead Valve |
Overhead Valve |
|
Ignition System.................................................................................. Solid-state w/Magneto Solid-state w/Magneto |
Solid-state w/Magneto |
|
Compression Ratio.......................................................................................... 8.6:1 9.5:1 |
9.5:1 |
|
Starter............................................................................................................ 12 Vdc 12 Vdc |
12Vdc |
|
Oil Capacity Including Filter..................................................................... Approx. 1.7 Qts Approx. 1.7 Qts. |
Approx. 1.7 Qts. |
|
Operating RPM............................................................................................... 3,600 3,600 |
3,600 |
|
Fuel Consumption |
|
|
Natural Gas .................... cu.ft./hr. |
|
|
........................................ 1/2 Load 66 152 |
156 |
|
........................................ Full Load 119 215 |
220 |
|
Liquid Propane.................ft3/hr(gal/hr) |
|
|
.........................................1/2 Load 30(0.82) 56(1.53) |
58(1.58) |
|
.........................................Full Load 54(1.47) 76(2.08) |
88(2.40) |
|
Required fuel pressure to generator fuel inlet at all load ranges - 5 to 7 inches of water column for natural gas, 11 to 14 inches of water col |
umn for LP gas |
|
CONTROLS |
|
|
Mode Switch |
|
|
-Auto .............................................................................................................................................. Automatic Start on Utility |
|
|
failure/7 day exerciser |
|
|
-Off ........................................................................................................................................... Stops unit. Power is removed |
|
|
Control and charger still operate |
|
|
-Manual/Test (start) ......................................................................................................................Start with starter control, unit |
|
|
stays on. If utility fails, transfer |
|
|
to load takes place. |
|
|
Engine Start Sequence Cyclic cranking: 7 sec. on, 7 rest |
|
|
(90 sec. maximum duration) |
|
|
Engine Warm-up .................................................................................................................................................... 10 seconds |
|
|
Engine Cool-Down .................................................................................................................................................... 1 minute |
|
|
Starter Lock-out ....................................................................................................................................... Starter cannot re-engage until |
|
|
5 sec. after engine has stopped. |
|
|
2.5 Amp Timed Trickle Battery Charger .................................................................................................................. Standard |
|
|
Automatic Voltage Regulator w/Overvoltage Protection ............................................................................................ Standard |
|
|
Automatic Low Oil Pressure Shutdown ..................................................................................................................... Standard |
|
|
Overspeed Shutdown ........................................................................................................................................... Standard, 72Hz |
|
|
High Temperature Shutdown .................................................................................................................................... Standard |
|
|
Overcrank Protection ................................................................................................................................................ Standard |
|
|
Safety Fuse .............................................................................................................................................................. Standard |
|
|
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with |
|
|
BS5514, ISO3046 and DIN6271). * Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum |
|
|
power decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 12° C (10° F) above 15.5° C (60°F). Home Standby - 7kW - 12kW - 15kW TRANSFER SWITCH & EMERGENCY LOAD CENTER Model 04389 (7kW) Model 04456 (12kW) Model 04390 (15kW) No. of Poles ........................................................................... 2 ........................................... 2 ........................................... 2 Current Rating (amps) .......................................................... 100 ..........................................100 ......................................... 100 Voltage Rating (VAC) ........................................................... 250 ......................................... 250 ......................................... 250 Utility Voltage Monitor (fixed) -Pick-up ................................................. 70% ....................................... 70% ........................................ 70% -Dropout ................................................ 60% ........................................ 60% ........................................ 60% Return to Utility ....................................... approx. 13 sec. ....................... approx. 13 sec. ....................... approx. 13 sec. Exerciser weekly for 12 minutes ...................................... Standard ................................ Standard ................................. Standard UL Listed .......................................................................... Standard ................................ Standard ................................. Standard Dimensions (H” x W” x D”) ........................................... 26.5 x 12.5 x 7 ...................... 26.5 x 12.5 x 7 ....................... 26.5 x 12.5 x 7 Total of Pre-wired Circuits ...................................................... 8 ........................................... 10 ........................................... 12 No. 15A 120V ..................................................... 5 ........................................... 3 ............................................. 5 No. 20A 120V ..................................................... 1 ........................................... 3 ............................................. 3 No. 15A 240V ..................................................... - ........................................... - ............................................ - No. 20A 240V ..................................................... - ........................................... 1 ............................................ 1 No. 30A 240V ..................................................... 1 ........................................... 1 ........................................... 1 Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts ........................................ 10,000 .................................... 10,000 .................................... 10,000 Transfer Switch Features • Electrically operated, mechanically-held contacts for fast, positive connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 160 millisecond transfer time. • Dual coil design. • Main contacts are silver plated or silver alloy to resist welding and sticking. • Nema 1 enclosure is standard on the 100 amp switch.
|
|